Healy - Science Seawater Requirements

Requirement Sampling Seawater Incubator Seawater Washdown Seawater
95% operation while in ice Yes Yes Yes
Flow rate 12 G/min at biochem lab 100-120 G/min at 01 level Bow Foc’sle 12 G/min (garden house flow) on fantail
Temperature differential between intake and service + 0.2 C (0.3F) original spec. More realistic might be 0.5 C + 1.0 C (1.8F) + 1.0 C (1.8F)
Manifold location Wet Lab, Biochem lab, science staging area, climate control chamber, each van position 01 level Bow Foc’sle.
Four manifolds with 25-30 Gallons/min each. Garden hose, freeze free fittings.
Main deck Fantail- two garden hose fittings
Pump redundancy Yes Yes Yes
Minimum residence time in seachest Yes No No
Special piping for minimal contamination Yes No No
Minimal contamination Yes No No